This rated capacity, in pounds, is listed at twice the flow rate. Grease Trap/FOG Interceptor Installation - Alpha Plumbing Rather, you will have to solve it when it becomes gross. The Uniform Plumbing Code (UPC) does not permit a grease interceptor to serve as a fixture trap and also prohibits the installation of a vent between the air intake on the flow control and the grease interceptor. With these traps, food and debris particles are caught before they pile up and pose an environmental or plumbing threat. Instead, you should have your used cooking oil properly collected and recycled whenever possible. As a national service provider, DAR PRO service technicians stay informed of the various municipal codes to ensure all service visits comply with current local, state and federal ordinances. The International Plumbing Code (IPC) 1002.1 (exception 3) allows a grease interceptor to serve as a fixture trap - where it is intended by the manufacturer to serve as a trap - for a single fixture or a combination sink of not more than three compartments so long as the vertical distance from the outlet of the fixture to the inlet of the interceptor is not more than 30 inches and the . Water from these sources enters a grease trap where it is separated - grease floats to the top of the trap and is removed while the wastewater exits through an outlet pipe into the city's sewer system. It costs municipalities and local authorities thousands of dollars in maintenance and has negative impacts on the environment. We are more than happy to remove the contents of the trap, but if a clog is the source of the overflow, a plumber will need to address the issue for the grease trap to function properly. The efficiency comes with a higher cost in terms of initial investment. A grease trap works by cooling warm or hot greasy water. Cooking with grease can be messy. It depends on which model plumbing code applies to the installation. For commercial establishments, consider an automatic option that can hold thousands of gallons worth of FOG. This causes the trap to fill up. Grease should never be poured down a drain, as it will solidify while traveling through the pipe and can cause clogging, backups and overflows. The grease traps work well with the low water pressure (less than 50 gallons per minute). Grease traps & grease management systems are designed to prevent fats, oils, & grease from entering your drainage system. Grease trap cleaning is one of the most unpleasant, odorous, labor-intensive jobs you'll ever ask of a kitchen employee. If you opt for the gravity grease traps, ensure they are pumped regularly. I found the exact same model online for $400.00 (including shipping). ASME A112.14.3 allows four types of ratings as follows: Type A - units with external flow control, with air intake (vent): directly connected, Type B - units with external flow control, without air intake (vent): directly connected, Type C - units without an external flow control: directly connected, Type D - units without an external flow control: indirectly connected. Installation. For compliance with the UPC this drawing would have to show both a vented external flow control and a trap and vent for the fixture. Essentially, a grease trap works by using gravity to separate heavier water from lighter fats. Failure to follow these laws and regulations may attract fines or even closure of your business. Usually, restaurants have under the sink grease traps set up in their kitchen. If your service provider is illegally dumping the material in a stream or other unauthorized location, you can be fined. /MediaBox [0 0 595.2200 842] Here are the answers you need to know! No. You can also find this point in a manual book. When was AR 15 oralite-eng co code 1135-1673 manufactured? Here are some other frequently asked questions about grease traps: If it is for your house, consider a small traditional grease trap that can hold up to 200 gallons. Some are installed inside; some are installed underground outside. For more details on why not, read the answer to Is it ok to put grease down the drain? The interceptor is placed into the trench where gravel is then poured to fill the space between the interceptor and the earth. FOG can become toxic over time. Were going to focus on residential grease traps but if you would like more information on commercial grease traps check out this article. The first connection in a trap connects the water source or sink to the trap body. 300 Litre Capacity Unique Design Below Ground Large Restaurant Hotel Free Delivery 35.00 + vat If pipe depth is an issue, each stackable 220 mm 4. Any damage and youll need to replace your gaskets. <> A majority of commercial cooking equipment - such as ranges, griddles, and fryers - require the use of an exhaust hood. As the waste stream flows through the orifice in the flow control device negative pressure is created, drawing in air from the air intake which is intended to mix with the waste water as it enters the grease interceptor aiding in separation efficiency. The frequency is higher in commercial areas while it is lower in homes. As we mentioned earlier, the location is significant when it comes to grease trap installation. Fix leaks on the spot. The automatic systems make use of a heating system that re-heats the FOG before skimming it into a collector bin. The above diagram would not be compliant with the UPC. Worse, there is a high risk of increased blockages and overflows. Lastly, the third connection is usually found on the lower right of the grease trap. Remove any Still Water This video gives you an accurate picture of how to do it yourself quite conveniently.Of course, cooking with grease is messy. Having a grease trap is actually a selling point your business can use to show they are helping the environment. Since all semi-automatic draw-off grease interceptors are certified to either PDI G101 or ASME A112.14.3 Type A (that I am aware of) an external vented flow control must be shown for compliance with the IPC. If left unchecked, this accumulation of waste can not only turn out to be an expensive process to undo but can also become extremely gross. Avoiding this issue can save you time and money. What You Need to Know About Grease Traps - Septic Maxx Water from these sources enters a grease trap where it is separated grease floats to the top of the trap and is removed while the wastewater exits through an outlet pipe into the citys sewer system. A major factor that will determine the cost of installation is the type of grease trap you have. Depending on your needs (flow rate, size of the restaurant, etc. When it comes to traps and vents for grease interceptors and the fixtures discharging to them, it's incumbent upon an engineer or contractor to identify and comply with local code requirements regardless what a manufacturer's drawing shows. Are grease traps a legal requirement? As long as a grease trap is properly maintained, you wont have to worry about having a blocked sewer system. Remove all solid waste from the grease interceptor. Both terms are referencing the same thing. Grease Trap / Fat Trap installation Details - YouTube The hydro-mechanical grease interceptors are typically installed under the sink or on the kitchen floor. Before installing the Grease Trap, you also need approval from your areas water authority and waste inspection department. Grease Trap Installation and Cost | Roto-Rooter Blog The unit shown is certified to ASME A112.14.3 Type C (without external flow control) with a built-in or integral flow control and does not require an air intake. Did Billy Graham speak to Marilyn Monroe about Jesus? The UPC does not include provisions for AAVs except as a part of an "Engineered Vent System" under section 912.0, much to the chagrin of engineers around the country. If it reaches the bottom, you should know that grease trap pumping is immediately required. Inspect grease traps and interceptors for food waste accumulation. Raleigh Location Why Walden's rule not applicable to small size cations. But for the most part, a grease trap installation is usually done for a restaurant, or institutional kitchens such as in schools, hospitals and even churches. The first connection connects to the sink or the wastewater source. A grease trap should be installed so that it is accessible to you so you can clean it and remove the content when it fills up. Properly Maintain Grease Traps and Interceptors to Prevent Introduction into the Sanitary Sewer System Witness all grease trap or interceptor cleaning/maintenance activities to ensure the Theyre quite easy to clean. We always prefer installing a grease trap that minimizes the waste content from the start. Thirdly, there is one last connection. Once in a while, Iget an email that contains a drawingor a photo of a grease interceptor installation with the question, "does this look right?" Installing a Grease Trap | The Whole Installation Process However, if you have multiple sinks at your place, you should place a grease interceptor outside to collect all the fat content. As such, grease interceptors are ideal for installation in large restaurants where there is a lot of grease flowing through the drains.